REVIEWS AND ORIGINAL ARTICLES |
From the Department of Pathophysiology, Medical Academy, Poznan, Poland.
The authors created transmesothelial ultrafiltration in vitro by
inducing an osmotic gradient (vasc-300 mOsm: meso-400 mOsm) across the
membrane. Calculated value of hydraulic conductivity of the mesothelium is
comparable with analogous value for endothelium of the microvessels.
KEY WORDS: Transmesothelial ultrafiltration; Mesothelial permeability; Hypertonicity.