PDI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Perit Dial Int 23(4): 368-374 2003
© 2003 International Society for Peritoneal Dialysis
This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Crabtree, J.
Right arrow Articles by Fishman, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Crabtree, J.
Right arrow Articles by Fishman, A
Peritoneal Dialysis International, Vol 23, Issue 4, 368-374
Copyright © 2003 by International Society for Peritoneal Dialysis


Clinical Trial

The efficacy of silver-ion implanted catheters in reducing peritoneal dialysis-related infections

JH Crabtree, RJ Burchette, RA Siddiqi, IT Huen, LL Hadnott, and A Fishman

Department of Surgery, Southern California Permanente Medical Group, Kaiser Permanente Bellflower Medical Center, Bellflower, California 90706, USA. John.H.Crabtree@kp.org

BACKGROUND: Dialysis-related infections are the commonest cause of catheter loss and transfer to hemodialysis. Surface modifications of the catheter that reduce infections are of major importance. OBJECTIVE: The efficacy of silver-ion treated catheters in reducing dialysis-related infections was tested. METHODS: The study design was a prospective, randomized controlled trial. Patients were implanted with either a silver-treated study catheter or a control catheter. Prospective collection of data included infectious complications and catheter survival. RESULTS: The subject groups were comprised of 67 silver-treated catheters and 72 control catheters. Demographic characteristics of the study and control groups were equal. Exit-site infection rates for the study group and control group (0.52 and 0.45 episodes/patient-year of dialysis respectively) were not different by Poisson regression analysis (p > 0.4). Peritonitis rates were identical for the two groups (0.37 episodes/patient-year) and were not different by Poisson analysis (p > 0.9). Antibiotic-free intervals between infections for the study and control groups were not significantly different for exit-site infections (p = 0.58), peritonitis (p = 0.44), or both infections combined (p = 0.47). Actuarial analyses showed no differences between the groups in the probability of remaining free of exit-site infection (p > 0.2) or peritonitis (p > 0.7). Similarly, catheter survival was not significantly different between the groups (p > 0.6). CONCLUSION: Surface modification of catheters with ion beam implantation of silver produced no clinical effect with respect to reducing dialysis-related infections.




This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
E. A. Brown
Peritonitis: limiting the damage
Nephrol. Dial. Transplant., August 1, 2005; 20(8): 1539 - 1541.
[Full Text] [PDF]


Home page
J Antimicrob ChemotherHome page
F. Furno, K. S. Morley, B. Wong, B. L. Sharp, P. L. Arnold, S. M. Howdle, R. Bayston, P. D. Brown, P. D. Winship, and H. J. Reid
Silver nanoparticles and polymeric medical devices: a new approach to prevention of infection?
J. Antimicrob. Chemother., December 1, 2004; 54(6): 1019 - 1024.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Multimed Inc. logo
Copyright © 2003 by Multimed Inc.