PDI 2009 ISDP LAC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Perit Dial Int 23(2): 146-150 2003
© 2003 International Society for Peritoneal Dialysis
This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anderstam, B
Right arrow Articles by Lindholm, B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anderstam, B
Right arrow Articles by Lindholm, B
Peritoneal Dialysis International, Vol 23, Issue 2, 146-150
Copyright © 2003 by International Society for Peritoneal Dialysis


Evaluation Studies

Determination of alpha-amylase activity in serum and dialysate from patients using icodextrin-based peritoneal dialysis fluid

B Anderstam, E Garcia-Lopez, O Heimburger, and B Lindholm

Division of Renal Medicine, Department of Clinical Science, Huddinge University Hospital, Karolinska Institutet, Stockholm, Sweden. bjorn.anderstam@klinvet.ki.se

OBJECTIVE: Low serum activity of alpha-amylase has been reported in peritoneal dialysis (PD) patients following treatment with icodextrin-based peritoneal dialysis fluid (IPDF). However, these results have been questioned because icodextrin interferes with the polysaccharide reagent included in the assay as a substrate for alpha-amylase in the sample. DESIGN: We adapted a routine method using p-nitrophenol maltoheptaoside as substrate for the analysis of total alpha-amylase in serum and dialysate from 27 patients using IPDF. Serum from 12 healthy volunteers and serum and dialysate from 19 PD patients using glucose-based peritoneal dialysis fluid (GPDF) were used as controls. For the PD patients, time on dialysis ranged from 1 to 24 months (mean 5.7 months) and time of exposure to IPDF ranged from 1 to 52 weeks. RESULTS: To test for interference and recovery, and thus to validate the alpha-amylase assay, samples were spiked with IPDF and synthetic alpha-amylase. This revealed that addition of up to 75% IPDF did not interfere with the assay. Furthermore, alpha-amylase was fully recovered when spiked in serum from patients treated with IPDF. We show that total alpha-amylase activity is considerably lower in the serum of IPDF patients (20.3 +/- 16.5 U/L, p < 0.001) than GPDF patients (85.5 +/- 51.7 U/L) and healthy persons (55.1 +/- 13.6 U/L). CONCLUSIONS: We have shown that the IL method (ILTest; Instrumentation Laboratory, Lexington, MA, USA) measures alpha-amylase activity in samples containing icodextrin metabolites. The clinical significance of reduced plasma alpha-amylase activity, as well as the relative importance of pancreatic versus salivary and tissue-bound alpha-amylase, in PD patients using IPDF is not known.




This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
S. J. Davies, E. G. Lopez, G. Woodrow, K. Donovan, J. Plum, P. Williams, A. C. Johansson, H.-P. Bosselmann, O. Heimburger, O. Simonsen, et al.
Longitudinal relationships between fluid status, inflammation, urine volume and plasma metabolites of icodextrin in patients randomized to glucose or icodextrin for the long exchange
Nephrol. Dial. Transplant., September 1, 2008; 23(9): 2982 - 2988.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Multimed Inc. logo
Copyright © 2003 by Multimed Inc.