Perit Dial Int 22(2): 229-233 2002
© 2002 International Society for Peritoneal Dialysis
This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Araujo Teixeira, M.
Right arrow Articles by Abensur, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Araujo Teixeira, M.
Right arrow Articles by Abensur, H
Peritoneal Dialysis International, Vol 22, Issue 2, 229-233
Copyright © 2002 by International Society for Peritoneal Dialysis


Articles

The relationship between ultrafiltrate volume with icodextrin and peritoneal transport pattern according to the peritoneal equilibration test

MR Araujo Teixeira, RF Pecoits-Filho, JE Romao Junior, E Sabbaga, MM Marcondes, and H Abensur

Nephrology Division, Hospital das Clinicas, University of Sao Paulo, Sao Paulo, Brazil. marea@uol.com.br

OBJECTIVE: To establish a relationship between peritoneal transport membrane pattern, analyzed by the peritoneal equilibration test (PET), and drained volume using icodextrin (7.5% Ico) and glucose (3.86% Glu) solutions. DESIGN: Thirty peritoneal dialysis patients were submitted to a standard 4-hour PET and divided into 4 transport categories based on dialysate-to-plasma ratio of creatinine (D/Pcr) and dialysate ratio of glucose at 4 and zero hours of the dwell (D4/D0). Patients were asked to perform exchanges for 2 consecutive nights in 10-hour dwells (2 L 3.86% Glu solution on the first night, and 2 L 7.5% Ico solution on the second night). The drained volume was measured and dialysate samples from the overnight exchanges were obtained for beta2-microglobulin (B2M) levels. RESULTS: PET classification using D/Pcr showed that 46.6% of the patients were high and high-average transporters, or 23.3% when D4/D0 was used. In spite of this difference, both methods showed significant correlation (p = 0.0001, r = 0.862). The mean drained volumes were similar for both solutions (for 3.86% Glu, 2696 +/- 369 mL; for 7.5% Ico, 2654 +/- 424 mL). The high and high-average transport patients classified by D4/D0 achieved a higher ultrafiltration with 7.5% Ico than with 3.86% Glu (p = 0.0235). When classified by D/Pcr, the difference was not significant (p = 0.2243). In the low and low-average transport patients classified by D/Pcr, we observed a significantly lower ultrafiltration when 7.5% Ico was used compared to 3.86% Glu solution (p = 0.0197). Using D4/D0, we saw a tendency toward lower ultrafiltration (p = 0.0719) in the same group. We then correlated the PET results and the difference between drained volume with 7.5% Ico and 3.86% Glu solution [deltaV (I-G)]. We found a significant negative correlation between D4/D0 and deltaV (I-G) (p = 0.002, r = -0.5390), and a positive correlation between D/Pcr and deltaV (I-G) (p = 0.005, r = 0.4932). The levels of B2M obtained with 7.5% Ico were higher than those obtained with 3.86% Glu solution (for 7.5% Ico, 9.47 +/- 6.71 microg/vol; for 3.86% Glu, 7.29 +/- 4.91 microg/vol; p = 0.004). Furthermore, we found significant correlation between the total amount of B2M obtained with 7.5% Ico solution and D4/D0 (p < 0.0001, r = -0.4493), and D/Pcr (p < 0.0001, r = 0.5431). CONCLUSION: Mean drained volume was similar between the two solution groups. High transporters, as defined by D4/D0, achieved higher ultrafiltration with 7.5% Ico than with 3.86% Glu solution. This is most likely due to the higher number of small pores in the peritoneal membrane. Low transporters, as classified by D/Pcr, achieved lower ultrafiltration with 7.5% Ico than with 3.86% Glu solution. The deltaV (I-G) and the PET results showed significant correlation, confirming that high transporters have a higher ultrafiltration volume with 7.5% Ico. The total B2M mass obtained with 7.5% Ico was greater than with 3.86% Glu solution and significantly higher in the high transport patients, indicating a larger number of small pores. Thus, the deltaV (I-G) could give us an idea of the peritoneal transport pattern in peritoneal dialysis patients.




This article has been cited by other articles:


Home page
J. Am. Soc. Nephrol.Home page
F. Finkelstein, H. Healy, A. Abu-Alfa, S. Ahmad, F. Brown, T. Gehr, K. Nash, M. Sorkin, S. Mujais, and on behalf of the Icodextrin High Transporter Trial
Superiority of Icodextrin Compared with 4.25% Dextrose for Peritoneal Ultrafiltration
J. Am. Soc. Nephrol., February 1, 2005; 16(2): 546 - 554.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Multimed Inc. logo
Copyright © 2002 by Multimed Inc.