PDI 2009 ISDP LAC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Perit Dial Int 19(Suppl_2): 176-178 1999
© 1999 International Society for Peritoneal Dialysis
This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, D.
Right arrow Articles by Oh, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, D.
Right arrow Articles by Oh, H.
Peritoneal Dialysis International, Vol 19, Issue Suppl_2, S176-S178
Copyright © 1999 by International Society for Peritoneal Dialysis


Articles

The effect of dialysate dwell on gastric emptying time in patients on continuous ambulatory peritoneal dialysis

DJ Kim, WH Kang, HY Kim, BH Lee, B Kim, SK Lee, DJ Oh, W Huh, and HY Oh

Department of Medicine, College of Medicine, Sung Kyun Kwan University, and Samsung Seoul Hospital, Korea.

METHODS AND PATIENTS: We evaluated gastric emptying time (GET) with a technetium (Tc) 99m-sulfur colloid gastric emptying scan in 11 patients on continuous ambulatory peritoneal dialysis (CAPD) (6 males, 5 females) and in 14 controls. We investigated the effect of dialysate dwell on GET by studying the subjects twice: once without dialysate in the abdomen (drained) and once with 2 L of dialysate in the abdomen (full). We also investigated the relationship between body surface area (BSA) and delayed gastric emptying. RESULTS: (1) The mean gastric emptying rate in 120 minutes in patients on CAPD when drained (67.8%+/-13.4%) was not different from that in controls (65.4%+/-8.6%). (2) The mean gastric emptying rate in 120 minutes in patients on CAPD when full was significantly slower than that when drained (55.6%+/-14.6% versus 67.8%+/-13.4%, p < 0.05). In four of the 11 patients (36.4%), gastric emptying was extremely delayed from normal to abnormal range when full. (3) The BSA of patients who had extremely delayed GET from normal to abnormal range was smaller than that of patients who had minimal delayed or unchanged GET when full (1.5+/-0.11 m2 versus 1.74+/-0.22 m2). CONCLUSION: This study showed that patients on CAPD had normal gastric emptying when drained, and that gastric emptying was delayed by dialysate dwell, especially in patients who has less than 1.5 m2 of body surface area. Therefore, we suggest that, based on adequacy, intermittent nocturnal peritoneal dialysis or a small volume of dialysate be considered for patients with small body surface area.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Multimed Inc. logo
Copyright © 1999 by Multimed Inc.