PDI 2009 ISDP LAC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Perit Dial Int 16(Suppl_1): 84-87 1996
© 1996 International Society for Peritoneal Dialysis
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Durand, P.
Right arrow Articles by Kessler, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Durand, P.
Right arrow Articles by Kessler, M
Peritoneal Dialysis International, Vol 16, Issue Suppl_1, S84-S87
Copyright © 1996 by International Society for Peritoneal Dialysis


Articles

Measurement of hydrostatic intraperitoneal pressure: a necessary routine test in peritoneal dialysis

PY Durand, J Chanliau, J Gamberoni, D Hestin, and M Kessler

ALTIR, Nancy, France.

This paper summarizes our clinical studies on hydrostatic intraperitoneal pressure (IPP), showing the interest of this measurement in routine clinical practice. IPP can easily be measured routinely be a simple and safe method: the measure of the column of dialysate in the peritoneal dialysis (PD) line before drainage, with point 0 located on the midaxillary line. The normal value is 12 +/- 2 cm of water (cm H2O) with an intraperitoneal volume (IPV) of 2 L, with linear increases of 2.2 cm H2O for each additional liter. IPP must be measured to estimate the tolerance of IPV: the maximal permissible IPV is reached for an IPP of 18 cm H2O, squaring with a decrease of 20% in vital capacity and sometimes arising before clinical symptomatology. However, IPP measured at rest could not predict PD mechanical complications (hernias, dialysis leakages, hemorrhoids, etc.), which are more dependent on parietal previous history or predisposition. IPP is significantly higher during the first three days after peritoneal catheter implantation (17 +/- 3 cm H2O) than during the 12 following days (10 +/- 4 cm H2O). It is recommended to postpone the start of PD until after catheter implantation, and patients should remain supine for the first three days. On the other hand, IPP strongly reduces the overall ultrafiltration (UF) volume: an increase of 1 cm H2O in IPP caused a decrease of 70 mL in global UF after two hours. Therefore, IPP should be measured in diagnosis of losses of UF. However, UF loss during peritonitis is not due to an increase of IPP.




This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
P. Ivarsen, J. V. Povlsen, and J. D. Jensen
Increasing fill volume reduces cardiac performance in peritoneal dialysis
Nephrol. Dial. Transplant., October 1, 2007; 22(10): 2999 - 3004.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. Dejardin, A. Robert, and E. Goffin
Intraperitoneal pressure in PD patients: relationship to intraperitoneal volume, body size and PD-related complications
Nephrol. Dial. Transplant., May 1, 2007; 22(5): 1437 - 1444.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
N. M. Selby, J. Fialova, J. O. Burton, and C. W. McIntyre
The haemodynamic and metabolic effects of hypertonic-glucose and amino-acid-based peritoneal dialysis fluids
Nephrol. Dial. Transplant., March 1, 2007; 22(3): 870 - 879.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Multimed Inc. logo
Copyright © 1996 by Multimed Inc.