PDI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Perit Dial Int 16(4): 393-397 1996
© 1996 International Society for Peritoneal Dialysis
This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simon, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simon, M
Peritoneal Dialysis International, Vol 16, Issue 4, 393-397
Copyright © 1996 by International Society for Peritoneal Dialysis


Articles

Peritoneal mesothelium in vitro: an electrophysiologic study

M Simon

Department of Pathophysiology, University Medical School, Poznan, Poland.

OBJECTIVE: In vitro electrophysiologic characterization of the peritoneal mesothelium as a barrier for ion transport during peritoneal dialysis. DESIGN: Experiments were performed on rat's mesentery and diaphragm. Electrophysiologic parameters of the isolated tissue were assessed in the modified Ussing system. RESULTS: We have shown that there are significant differences between electrophysiological parameters of the parietal and visceral peritoneum. The value of the potential difference across the parietal mesothelium lining the abdominal part of the diaphragm (PDmpt) was 0.26 +/- 0.03 mV (mean +/- SEM), with a positive charge recorded from the apical side of the mesothelium. Electrical resistance of the mesothelial monolayer (Rmpt) was Rmpt = 13.6 +/- 1.3 omega.cm2 and 1.4 +/- 0.2 omega.cm2 for the tissue isolated from the diaphragm and mesentery, respectively. Both the mechanical and chemical procedures used for the preparation of the peritoneal membrane model from the diaphragm have been shown to produce similar values of electrophysiological parameters. CONCLUSION: The electrophysiologic approach presented here may be a useful tool for studies of highly permeable biological membranes such as the peritoneal mesothelium. The mesothelial tissue isolated from the rat diaphragm has been shown to be a suitable model for electrophysiologic studies of the peritoneum as assessed by the values of the PDmpt and Rmpt parameters.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Multimed Inc. logo
Copyright © 1996 by Multimed Inc.