PDI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Perit Dial Int 14(4): 324-326
1994
© 1994 International Society for Peritoneal Dialysis
This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jindal, K.
Right arrow Articles by Hirsch, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jindal, K.
Right arrow Articles by Hirsch, D.
Peritoneal Dialysis International, Vol 14, Issue 4, 324-326
Copyright © 1994 by International Society for Peritoneal Dialysis


Articles

Excellent technique survival on home peritoneal dialysis: results of a regional program

KK Jindal and DJ Hirsch

Nova Scotia-Prince Edward Island Regional Home Dialysis Program, Department of Medicine, Dalhousie University, Halifax, Canada.

OBJECTIVE: To examine peritoneal dialysis technique survival in our regional, continuous ambulatory peritoneal dialysis (CAPD) program. DESIGN: Retrospective analysis. SETTING: Tertiary care dialysis program at an academic medical center. PATIENTS: 155 patients representing all those in the peritoneal dialysis program between October 1, 1987 and October 1, 1990. OUTCOME MEASURES: The study analyzed patient and technique survival as well as the reasons for discontinuation of dialysis. In addition, the incidence and type of peritonitis and exit-site infection were also analyzed. RESULTS: Three-year actuarial patient survival was 66% and three-year technique survival was 86%, with data censored for death and transplant patients. Fifty-seven percent of transfers to hemodialysis were due to peritonitis, usually fungal or multiorganism bacterial. Only 1 patient failed due to exit-site and tunnel infection, and 1 due to inadequate dialysis. The catheter removal rate was 0.04 per patient-year. CONCLUSIONS: Excellent CAPD technique survival can be achieved if exit-site and tunnel infection rates are low.




This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
R. Rao, D. Ansell, J. A. Gilg, S. J. Davies, E. J. Lamb, and C. R. V. Tomson
Effect of change in renal replacement therapy modality on laboratory variables: a cohort study from the UK Renal Registry
Nephrol. Dial. Transplant., September 1, 2009; 24(9): 2877 - 2882.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Multimed Inc. logo
Copyright © 1994 by Multimed Inc.