PDI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Perit Dial Int 14(2): 163-167 1994
© 1994 International Society for Peritoneal Dialysis
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Deutschendorf, A.
Right arrow Articles by Mason, P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Deutschendorf, A.
Right arrow Articles by Mason, P
Peritoneal Dialysis International, Vol 14, Issue 2, 163-167
Copyright © 1994 by International Society for Peritoneal Dialysis


Articles

Control of microwave heating of peritoneal dialysis solutions

AF Deutschendorf, RE Wenk, J Lustgarten, and P Mason

OBJECTIVE: To determine if microwave heating of dialysis solutions to 37 degrees C produced focal overheating (hot spots) and caramelization of dextrose. DESIGN: In vitro determination of conditions for controlling time, temperature, and procedures. Bags had been stored at ambient room temperature. MAIN OUTCOME MEASURES: Solution and external bag surface temperature determinations. Dextrose degradation products determined spectrophotometrically. Microscopy for potential caramel precipitates. RESULTS: A microwave oven with no rotation tray produced uneven heating of bags of two commercially available concentrations of dialysis solutions. The greatest hot spots were evident in spike ports. External bag surface temperatures were within 0.20 degrees C of reservoir temperatures. Initial solution temperatures correlated with temperatures of the solutions after microwave heating (r = 0.895). No statistically significant differences were found between dextrose degradation product concentrations of unheated and heated solutions, including hot spots. No precipitates were observed microscopically. CONCLUSIONS: Despite the presence of solution hot spots in bag infusion ports, 37 degrees C temperatures were achievable in the bag reservoirs with no evidence of increased glucose degradation. This outcome is assured if the initial temperature and the microwave conditions (procedure, time, mixing of solution) are held constant, and the external bag temperatures are measured after heating.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Multimed Inc. logo
Copyright © 1994 by Multimed Inc.